BUSHING REINFORCED INSULATORS

The bushing insulators are produced for switchgears of both indoor and outdoor installation. The insulators are intended for an insulation and mounting of the current-carrying parts in electrical devices, switchgears of power stations and substations, packaged switchgears, compounds with outdoor switchgears or transmission lines of alternating voltage from 6 to 35 kV with a frequency up to 100 Hz. The insulators are reinforced with flanges made of cast iron or aluminum alloy using portland cement. The busbars are made of aluminum.
| Insulator name |
Designation of the drawing |
GOST, TU, IEK |
Voltage class, kV |
The length of insulation distance is not less than, cm |
N, mm |
D outer, mm |
Weight, kg |
Rough drawing |
| nom. |
prev. deviation + -10% |
| IP-6/400-3,75 UHL2 |
IMZHK.686152.003SB |
GOST 22229-83 |
6 |
12 |
385 |
165 |
3,6 |
0,36 |
 |
| IP-10/630-7,5 UHL2 |
IMZHK.686152.003-05SB |
GOST 22229-83 |
10 |
20 |
470 |
205 |
6,3 |
0,63 |
 |
| IP-10/1000-7,5 U3 |
INYAZH.686153.013SB (2IKH.803.064SB) |
GOST 22229-83 |
10 |
— |
500 |
190×190 |
6,0 |
0,6 |
 |
| IP-10/1600-7,5 U3 |
INYAZH.686153.012SB (2IKH.803.065SB) |
GOST 22229-83 |
10 |
— |
500 |
190×190 |
6,8 |
0,68 |
 |
| IP-24/31500-30 UHL2 for nuclear power plants |
ILYAN.686155.017SB |
GOST 22229-83 |
24 |
40 |
545 |
1030 |
239,0 |
23,9 |
 |
| IPE-6 U2 for excavator pantographs |
INYAZH.686152.001SB (2IKH.803.077СБ) |
TU 16-528.084-76 |
6 |
— |
560 |
340 |
35,0 |
3,5 |
 |
| IPE-10-1 U2 |
NIYUD.686153.021SB |
Design document |
10 |
— |
630 |
340 |
46,0 |
4,6 |
 |
| MGo-110 U1 |
ITJSH.686112.003SB (6VD.280.003) |
TU 16-528.003-72 |
— |
190 |
1100 |
408 |
137,0 |
13,7 |
 |
| MGg-110 U1 |
ITJSH.686155.001SB
(6VD.280.001) |
TU 16-528.003-72 |
— |
106 |
670 |
430 |
92,0 |
9,2 |
 |
| IPU-10/630-7,5-I UHL1 oval flange |
NIYUD.686153.020SB |
GOST 22229-83 |
10 |
30 |
580 |
215 |
6,5 |
0,65 |
 |
The following letters and figures in the conventional value of IP, IPU, IPR, IPE insulator types denote:
I – insulator;
P – bushing;
U – enhanced performance of external insulation (category B according to GOST 9920-89);
P – ribbed;
E – excavating;
6; 10; 24; 35 – nominal voltage, kV;
400; 630; 1000; 1600; 31500 – nominal current, A;
3.75; 7.5; 30 – minimum breaking force while bending, kN;
I – modification;
UHL, U, T – climatic version for the moderate, cold and tropical areas;
1; 2; 3 – placement (operation) category, as relevant, outdoors, under the shelters, indoors according to GOST 15150-69.
Insulators MGo-110 U1, MGg-110 U1 are used in circuit breakers of MG-35 and MG-110 types for repair purposes and are designed for operation at outdoor substations as bearing supports, insulators of an interrupting chamber, are in a use as weather protection for pot-type small-oil volume circuit breakers.
The following letters and figures in the conventional value of insulator types denote:
MG – for pot-type small-oil volume circuit breaker;
g – insulator of interrupting chamber of a circuit breaker;
o – insulator being in a use as the bearing supports;
110 – nominal voltage, in kilovolts;
U – climatic version;
1 – placement category.
BUSHING UNREINFORCED INSULATORS
Material of the insulation part is a ceramic electrotechnical material of a subgroup 110 GOST 20419-83. They meet the requirements of GOST 5862-79.
| Insulator name |
Designation of the drawing |
GOST, IEK |
Voltage class, kV |
The length of insulation distance is not less than, cm |
N, mm |
D outer, mm |
Weight, kg |
Rough drawing |
| nom. |
prev. deviation + -10% |
| IPR-6-I UHL 2 |
NIYUD. 390-01 |
GOST 5862-79 |
6 |
— |
160 |
80 |
1,2 |
0,12 |
 |
| PNK-3 UHL 1 |
NIYUD.757523.062 |
GOST 5862-79 |
3 |
— |
115 |
90 |
0,42 |
±7% 0,029 |
 |
| PNK-6 UHL 1 |
NIYUD.757523.063 |
GOST 5862-79 |
6 |
— |
155 |
90 |
0,645 |
±7% 0,045 |
 |
| PNK-10 UHL 1 |
NIYUD.757523.064 |
GOST 5862-79 |
10 |
— |
195 |
90 |
0,87 |
±7% 0,06 |
 |
| PNK-10 UHL |
NIYUD.446 |
GOST 5862-79 |
10 |
30 |
195 |
97 |
1,00 |
0,1 |
 |
| IK-6 |
2IP.813.106 (E-104) (KN-6) |
GOST 5862-79 |
6 |
18 |
192 |
100 |
1,00 |
0,1 |
 |
| IK-10 |
2IP.813.107 (E-105) (KN-10) |
GOST 5862-79 |
10 |
20 |
247 |
100 |
1,60 |
0,16 |
 |
| Pr-Vr-U-22 |
ISHUM.757523.079 (5933) (8IV.813.049) |
GOST 5862-79 |
20 |
40 |
500 |
180 |
10,00 |
1,0 |
 |
| Pr-Vr-U-38 |
INSHYU.757523.041 |
GOST 5862-79 |
35 |
— |
704 |
260 |
20,00 |
2,0 |
 |
| Pr-A-U-38 |
INYAZH.757523.016(5925а) (2IKH.813.221) |
GOST 5862-79 |
35 |
— |
550 |
190 |
13,10 |
1,31 |
 |
| Pr-A-22 |
ИЛЮТ.757513.058 (2036) (2IKH.813.222) |
GOST 5862-79 |
20 |
— |
449 |
140 |
5,0 |
0,5 |
 |
| Pr-Vr-11 |
ISHUM.757523.055 (5861) (2IKH.813.224) |
GOST 5862-79 |
10 |
20 |
400 |
150 |
3,40 |
0,34 |
 |
| Pr-Vr-11 |
INYAZH.757523.068 (2530) (2IKH.813.233) |
GOST 5862-79 |
10 |
20 |
400 |
150 |
5,40 |
0,54 |
 |
| PM-3А |
ИМБШ.757523.058 (5505) (2IKH.813.094) |
GOST 5862-79 |
6 |
— |
375 |
98 |
3,80 |
0,38 |
 |
| PM-3И |
INYAZH.757523.015 (E-55) (2IKH.813.215) |
GOST 5862-79 |
10 |
— |
425 |
114 |
4,20 |
0,42 |
 |
| IRSH-6 |
INYAZH.757513.022 (5504) (2IKH.813.093) |
GOST 5862-79 |
— |
— |
148 |
124 |
1,46 |
0,146 |
 |
| 8ASH.720.018 |
4142.686152.350Р-023-05 |
GOST 5862-79 |
1 |
— |
45 |
75 |
0,3 |
0,03 |
 |
| 8ASH.720.020 |
4142.686152.350Р-02-03-02 |
GOST 5862-79 |
1 |
— |
94 |
100 |
0,89 |
0,089 |
 |
| ЗТ 49 |
INYAZH.757513.017 (2IKH.813.231) |
GOST 5862-79 |
16 |
— |
330 |
250 |
17,60 |
1,76 |
 |
| ЗТ-1172 |
INYAZH.757523.039 (2IKH.813.226) |
GOST 5862-79 |
20 |
— |
272 |
240 |
11,30 |
1,13 |
 |
| PMА-10-1 UHL 2 |
NIYUD.757523.051 |
GOST 5862-79 |
10 |
35 |
320 |
100 |
2,60 |
0,26 |
 |
| IPK-10/1600-5 U3 |
NIYUD.757532.002 (8IKH.720.056) |
GOST 5862-79 |
10 |
— |
250 |
160 |
4,00 |
0,4 |
 |
| IPK-10/2000-10 U3 |
NIYUD.757532.001 (8IKH.720.010) |
GOST 5862-79 |
10 |
— |
250 |
210 |
6,90 |
0,69 |
 |
| IPK-10/4000-15 U3 |
NIYUD.757532.003 (E-250) (8IKH.720.053) |
GOST 5862-79 |
10 |
— |
270 |
280 |
13,00 |
1,3 |
 |
| IK-10-I-UHL 1 |
NIYUD.757523.107 (2ИП.813.115) |
GOST 5862-79 |
10 |
30 |
295 |
130 |
2,38 |
0,238 |
 |
| IK-10-IV-UHL 1 |
INSHYU.757523.135-03 |
GOST 5862-79 |
10 |
30 |
295 |
130 |
2,38 |
0,238 |
 |
| IP-10-100-I О2 |
INYUM.686153.002-02-01 |
GOST 5862-79 |
10 |
21 |
200 |
170 |
5,30 |
0,53 |
 |
| IP-10-120 О2 |
INYUM.686153.002-03 |
GOST 5862-79 |
10 |
21 |
200 |
190 |
5,90 |
0,59 |
 |
| Insulator |
ISHUM.757523.024 (5947) |
GOST 5862-79 |
— |
— |
210 |
100 |
1,8 |
0,18 |
 |
| Insulator |
ISHUM.757523.080 (E-6307) |
GOST 5862-79 |
10 |
— |
165 |
75 |
0,9 |
0,09 |
 |
| Insulator |
INYUM.757523.025 (3111) |
GOST 5862-79 |
6 |
— |
60 |
85 |
0,38 |
0,038 |
 |
| Insulator (GAR-2-11912) |
INYAZH.757523.007 (E-115) (2IKH.813.177) |
GOST 5862-79 |
6 |
— |
485 |
235 |
15,5 |
1,55 |
 |
| Insulator (GAR-3-14172) |
INYAZH.757523.017 (2IKH.813.203) |
GOST 5862-79 |
— |
— |
247 |
100 |
3,2 |
0,32 |
 |
| Insulator (BU 7.890.088) |
INYAZH.757523.018 (2IKH.813.197) |
GOST 5862-79 |
25 |
— |
170 |
87 |
0,93 |
0,093 |
 |
| Insulator (BU-7-890.029) |
INYAZH.757523.019 (2IKH.813.200) |
GOST 5862-79 |
— |
— |
170 |
75 |
0,7 |
0,07 |
 |
| Insulator (BU 7.890.087) |
ILYAN.757523.081 |
GOST 5862-79 |
40 |
— |
273 |
148 |
5,7 |
0,57 |
 |
| Insulator (3А7.890.143) |
INYAZH.757523.014 (2IKH.813.206) |
GOST 5862-79 |
20 |
— |
153 |
148 |
3,3 |
0,33 |
 |
| Insulator |
INYAZH.757513.024 (4611) (2IKH.813.201) |
GOST 5862-79 |
10 |
— |
230 |
115 |
2,12 |
2,12 |
 |
| Insulator |
INYAZH.757513.032 (3110) |
GOST 5862-79 |
3 |
— |
76 |
85 |
0,47 |
0,047 |
 |
| Insulator |
INYAZH.757523.089 (5961) (2IKH.813.186) |
GOST 5862-79 |
6 |
— |
227 |
120 |
2,2 |
0,22 |
 |
| Bushing insulator |
INYAZH 757523.097 (МО.874.001) (2IKH.813.255) |
GOST 5862-79 |
6 |
— |
120 |
86 |
0,57 |
0,057 |
 |
| Bushing insulator |
INYAZH 757523.097-01 (МО.874.001) (2IKH.813.255) |
GOST 5862-79 |
10 |
— |
152 |
86 |
0,72 |
0,072 |
 |
| Insulator |
IBSH.757513.056 2IKH.813.210 (4855) |
GOST 5862-79 |
3 |
— |
95 |
100 |
0,74 |
0,074 |
 |
| Insulator |
INYAZH.757523.094 (5554) (2IKH.813.207) |
GOST 5862-79 |
— |
— |
138 |
55 |
0,34 |
0,034 |
 |
| Insulator |
ISHUM.757513.060 (4746) |
GOST 5862-79 |
— |
— |
42 |
50 |
0,1 |
0,01 |
 |
| Three-cell insulator |
ISHUM.757513.037 (2IKH.813.230) |
GOST 5862-79 |
6 |
— |
244 |
125 |
2,5 |
0,25 |
 |
| Insulator |
BILT.757532.006 (8ТХ.720.516) |
GOST 5862-79 |
20 |
— |
272 |
196 |
7,7 |
0,77 |
 |
| Insulator |
IR 8.720.003 (OVPR-10) |
GOST 5862-79 |
10 |
20 |
260 |
160 |
5,87 |
0,587 |
 |
| Insulator |
NIYUD.757513.020 |
GOST 5862-79 |
10,5 |
— |
205 |
155 |
2,6 |
±7% 0,182 |
 |
| Пр ТО 40,5 |
NIYUD.768 |
IEK 62155:2003 |
40,5 |
1050 |
540 |
285 |
33,0 |
3,3 |
 |
| Пр ТО 24 |
NIYUD.767 |
IEK 62155:2003 |
24 |
— |
380 |
210 |
10,0 |
1,0 |
 |
The following letters and figures in the conventional value of IK insulator type denote:
I – insulator;
K – for the end bells;
6; 10 – nominal voltage, kV;
I; IV – structural design;
UHL, T – climatic version;
1 – placement category.
PM-3I; PM-3A – bushing insulators for oil circuit breakers. The are intended for an insulation of current-carrying parts of oil circuit breakers.
PR-VR-11; PR-А-U-38 – bushing unreinforced insulators for power current transformers.
ZT-1172; ZT-49; BILT. 757532.006 – bushing ceramic non-reinforced insulators for electrical machines. They are intended for the incoming units of electrical machines and turbine-type generators.
РС-3; РС-6; RS-10 – antenna insulators for various communication units, antenna system.
PNK-10 UHL – bushing unreinforced insulators for coupling capacitors.
The following letters and figures in the conventional value of PNK insulator type denote:
P – bushing;
N – externally mounted;
K – condenser;
10 – voltage class, kV;
UHL – climatic version;
The IPK insulators are ceramic bushing unreinforced externally mounted insulators for packaged switchgears.
The following letters and figures in the conventional value of insulator type denote:
I – insulator;
P – bushing;
K – for packaged switchgears;
10 – nominal voltage, kV;
1600; 2000; 4000 – nominal current, A;
7.5; 10; 15 – minimum breaking force while bending, kN;
U, T – climatic version for the moderate and tropical areas;
3 – placement category (indoors) according to GOST 15150-69