Bushing insulators

BUSHING REINFORCED INSULATORS

izol-prokh-arm

The bushing insulators are produced for switchgears of both indoor and outdoor installation. The insulators are intended for an insulation and mounting of the current-carrying parts in electrical devices, switchgears of power stations and substations, packaged switchgears, compounds with outdoor switchgears or transmission lines of alternating voltage from 6 to 35 kV with a frequency up to 100 Hz. The insulators are reinforced with flanges made of cast iron or aluminum alloy using portland cement. The busbars are made of aluminum.

Insulator name Designation of the drawing GOST, TU, IEK Voltage class, kV The length of insulation distance is not less than, cm N, mm D outer, mm Weight, kg Rough drawing
nom. prev. deviation + -10%
IP-6/400-3,75 UHL2 IMZHK.686152.003SB GOST 22229-83 6 12 385 165 3,6 0,36
IP-10/630-7,5 UHL2 IMZHK.686152.003-05SB GOST 22229-83 10 20 470 205 6,3 0,63
IP-10/1000-7,5 U3 INYAZH.686153.013SB (2IKH.803.064SB) GOST 22229-83 10 500 190×190 6,0 0,6
IP-10/1600-7,5 U3 INYAZH.686153.012SB (2IKH.803.065SB) GOST 22229-83 10 500 190×190 6,8 0,68
IP-24/31500-30 UHL2 for nuclear power plants ILYAN.686155.017SB GOST 22229-83 24 40 545 1030 239,0 23,9
IPE-6 U2 for excavator pantographs INYAZH.686152.001SB (2IKH.803.077СБ) TU 16-528.084-76 6 560 340 35,0 3,5
IPE-10-1 U2 NIYUD.686153.021SB Design document 10 630 340 46,0 4,6
MGo-110 U1 ITJSH.686112.003SB (6VD.280.003) TU 16-528.003-72 190 1100 408 137,0 13,7
MGg-110 U1 ITJSH.686155.001SB
(6VD.280.001)
TU 16-528.003-72 106 670 430 92,0 9,2
IPU-10/630-7,5-I UHL1 oval flange NIYUD.686153.020SB GOST 22229-83 10 30 580 215 6,5 0,65

The following letters and figures in the conventional value of IP, IPU, IPR, IPE insulator types denote:

I – insulator;

P – bushing;

U – enhanced performance of external insulation (category B according to GOST 9920-89);

P – ribbed;

E – excavating;

6; 10; 24; 35 – nominal voltage, kV;

400; 630; 1000; 1600; 31500 – nominal current, A;

3.75; 7.5; 30 – minimum breaking force while bending, kN;

I – modification;

UHL, U, T – climatic version for the moderate, cold and tropical areas;

1; 2; 3 – placement (operation) category, as relevant, outdoors, under the shelters, indoors according to GOST 15150-69.

Insulators MGo-110 U1, MGg-110 U1 are used in circuit breakers of MG-35 and MG-110 types for repair purposes and are designed for operation at outdoor substations as bearing supports, insulators of an interrupting chamber, are in a use as weather protection for pot-type small-oil volume circuit breakers.

The following letters and figures in the conventional value of insulator types denote:

MG – for pot-type small-oil volume circuit breaker;

g – insulator of interrupting chamber of a circuit breaker;

o – insulator being in a use as the bearing supports;

110 – nominal voltage, in kilovolts;

U – climatic version;

1 – placement category.

BUSHING UNREINFORCED INSULATORS

Material of the insulation part is a ceramic electrotechnical material of a subgroup 110 GOST 20419-83. They meet the requirements of GOST 5862-79.

Insulator name Designation of the drawing GOST, IEK Voltage class, kV The length of insulation distance is not less than, cm N, mm D outer, mm Weight, kg Rough drawing
nom. prev. deviation + -10%
IPR-6-I UHL 2 NIYUD. 390-01 GOST 5862-79 6 160 80 1,2 0,12
PNK-3 UHL 1 NIYUD.757523.062 GOST 5862-79 3 115 90 0,42 ±7% 0,029
PNK-6 UHL 1 NIYUD.757523.063 GOST 5862-79 6 155 90 0,645 ±7% 0,045
PNK-10 UHL 1 NIYUD.757523.064 GOST 5862-79 10 195 90 0,87 ±7% 0,06
PNK-10 UHL NIYUD.446 GOST 5862-79 10 30 195 97 1,00 0,1
IK-6 2IP.813.106 (E-104) (KN-6) GOST 5862-79 6 18 192 100 1,00 0,1
IK-10 2IP.813.107 (E-105) (KN-10) GOST 5862-79 10 20 247 100 1,60 0,16
Pr-Vr-U-22 ISHUM.757523.079 (5933) (8IV.813.049) GOST 5862-79 20 40 500 180 10,00 1,0
Pr-Vr-U-38 INSHYU.757523.041 GOST 5862-79 35 704 260 20,00 2,0
Pr-A-U-38 INYAZH.757523.016(5925а) (2IKH.813.221) GOST 5862-79 35 550 190 13,10 1,31
Pr-A-22 ИЛЮТ.757513.058 (2036) (2IKH.813.222) GOST 5862-79 20 449 140 5,0 0,5
Pr-Vr-11 ISHUM.757523.055 (5861) (2IKH.813.224) GOST 5862-79 10 20 400 150 3,40 0,34
Pr-Vr-11 INYAZH.757523.068 (2530) (2IKH.813.233) GOST 5862-79 10 20 400 150 5,40 0,54
PM-3А ИМБШ.757523.058 (5505) (2IKH.813.094) GOST 5862-79 6 375 98 3,80 0,38
PM-3И INYAZH.757523.015 (E-55) (2IKH.813.215) GOST 5862-79 10 425 114 4,20 0,42
IRSH-6 INYAZH.757513.022 (5504) (2IKH.813.093) GOST 5862-79 148 124 1,46 0,146
8ASH.720.018 4142.686152.350Р-023-05 GOST 5862-79 1 45 75 0,3 0,03
8ASH.720.020 4142.686152.350Р-02-03-02 GOST 5862-79 1 94 100 0,89 0,089
ЗТ 49 INYAZH.757513.017 (2IKH.813.231) GOST 5862-79 16 330 250 17,60 1,76
ЗТ-1172 INYAZH.757523.039 (2IKH.813.226) GOST 5862-79 20 272 240 11,30 1,13
PMА-10-1 UHL 2 NIYUD.757523.051 GOST  5862-79 10 35 320 100 2,60 0,26
IPK-10/1600-5 U3 NIYUD.757532.002 (8IKH.720.056) GOST 5862-79 10 250 160 4,00 0,4
IPK-10/2000-10 U3 NIYUD.757532.001 (8IKH.720.010) GOST 5862-79 10 250 210 6,90 0,69
IPK-10/4000-15 U3 NIYUD.757532.003 (E-250) (8IKH.720.053) GOST 5862-79 10 270 280 13,00 1,3
IK-10-I-UHL 1 NIYUD.757523.107 (2ИП.813.115) GOST 5862-79 10 30 295 130 2,38 0,238
IK-10-IV-UHL 1 INSHYU.757523.135-03 GOST 5862-79 10 30 295 130 2,38 0,238
IP-10-100-I О2 INYUM.686153.002-02-01 GOST 5862-79 10 21 200 170 5,30 0,53
IP-10-120 О2 INYUM.686153.002-03 GOST 5862-79 10 21 200 190 5,90 0,59
Insulator ISHUM.757523.024 (5947) GOST  5862-79 210 100 1,8 0,18
Insulator ISHUM.757523.080 (E-6307) GOST 5862-79 10 165 75 0,9 0,09
Insulator INYUM.757523.025 (3111) GOST 5862-79 6 60 85 0,38 0,038
Insulator (GAR-2-11912) INYAZH.757523.007 (E-115) (2IKH.813.177) GOST 5862-79 6 485 235 15,5 1,55
Insulator (GAR-3-14172) INYAZH.757523.017 (2IKH.813.203) GOST 5862-79 247 100 3,2 0,32
Insulator (BU 7.890.088) INYAZH.757523.018  (2IKH.813.197) GOST 5862-79 25 170 87 0,93 0,093
Insulator (BU-7-890.029) INYAZH.757523.019 (2IKH.813.200) GOST 5862-79 170 75 0,7 0,07
Insulator (BU 7.890.087) ILYAN.757523.081 GOST  5862-79 40 273 148 5,7 0,57
Insulator (3А7.890.143) INYAZH.757523.014 (2IKH.813.206) GOST 5862-79 20 153 148 3,3 0,33
Insulator INYAZH.757513.024 (4611) (2IKH.813.201) GOST 5862-79 10 230 115 2,12 2,12
Insulator INYAZH.757513.032 (3110) GOST 5862-79 3 76 85 0,47 0,047
Insulator INYAZH.757523.089 (5961) (2IKH.813.186) GOST  5862-79 6 227 120 2,2 0,22
Bushing insulator INYAZH 757523.097 (МО.874.001) (2IKH.813.255) GOST 5862-79 6 120 86 0,57 0,057
Bushing insulator INYAZH 757523.097-01 (МО.874.001) (2IKH.813.255) GOST 5862-79 10 152 86 0,72 0,072
Insulator IBSH.757513.056 2IKH.813.210 (4855) GOST 5862-79 3 95 100 0,74 0,074
Insulator INYAZH.757523.094 (5554) (2IKH.813.207) GOST 5862-79 138 55 0,34 0,034
Insulator ISHUM.757513.060 (4746) GOST 5862-79 42 50 0,1 0,01
Three-cell insulator ISHUM.757513.037 (2IKH.813.230) GOST 5862-79 6 244 125 2,5 0,25
Insulator BILT.757532.006  (8ТХ.720.516) GOST  5862-79 20 272 196 7,7 0,77
Insulator IR 8.720.003   (OVPR-10) GOST 5862-79 10 20 260 160 5,87 0,587
Insulator NIYUD.757513.020 GOST  5862-79 10,5 205 155 2,6 ±7% 0,182
Пр ТО 40,5 NIYUD.768 IEK 62155:2003 40,5 1050 540 285 33,0 3,3
Пр ТО 24 NIYUD.767 IEK 62155:2003 24 380 210 10,0 1,0

The following letters and figures in the conventional value of IK insulator type denote:

I – insulator;

K – for the end bells;

6; 10 – nominal voltage, kV;

I; IV – structural design;

UHL, T – climatic version;

1 – placement category.

PM-3I; PM-3A – bushing insulators for oil circuit breakers. The are intended for an insulation of current-carrying parts of oil circuit breakers.

PR-VR-11; PR-А-U-38 – bushing unreinforced insulators for power current transformers.

ZT-1172; ZT-49; BILT. 757532.006 – bushing ceramic non-reinforced insulators for electrical machines. They are intended for the incoming units of electrical machines and turbine-type generators.

РС-3; РС-6; RS-10 – antenna insulators for various communication units, antenna system.

PNK-10 UHL – bushing unreinforced insulators for coupling capacitors.

The following letters and figures in the conventional value of PNK insulator type denote:

P – bushing;

N – externally mounted;

K – condenser;

10 – voltage class, kV;

UHL – climatic version;

The IPK insulators are ceramic bushing unreinforced externally mounted insulators for packaged switchgears.

The following letters and figures in the conventional value of insulator type denote:

I – insulator;

P – bushing;

K – for packaged switchgears;

10 – nominal voltage, kV;

1600; 2000; 4000 – nominal current, A;

7.5; 10; 15 – minimum breaking force while bending, kN;

U, T – climatic version for the moderate and tropical areas;

3 – placement category (indoors) according to GOST 15150-69